RCBOs are the usual call when you want fault protection and overcurrent protection on the same way, so you are not relying on a shared device to take out the whole board. Choose the pole count, trip type and breaking capacity to suit the circuit and board spec. Most call-backs come from fitting the wrong format for the enclosure, or from treating every circuit the same when the load and arrangement are different.
Schneider Electric Easy9 Miniature Circuit Breaker - 6kA 32A SP Type B
32A B-curve RCBO with 6kA breaking capacity
Hager RCBO SP C - 10A 30mA 10kA
Single-pole RCBO, C curve, 10A 30mA Type A, 10kA, 1 module
Schneider Electric Acti9 iC60H PoN RCBO - 32A 30mA Type B
Schneider Acti9 iC60H PoN 32A Type B 30mA RCBO
Altrion Bi-Directional SL&N RCBO - 50A Solid Neutral
50A bi-directional RCBO with solid neutral, Type A RCD, 10kA
Fusebox Mini AFDD RCBO - 6A 1P+N switched B curve 6kA 30mA Type A
6A 1P+N switched B curve 6kA 30mA Type A Mini AFDD RCBO
Hager 45A Single Pole RCBO - 1 Module B Curve 6kA 30mA Type A
45A single pole RCBO with B curve, 6kA, 30mA Type A
Fusebox AFDD RCBO - 25A 30mA 1P+N Type A
25A 30mA AFDD RCBO 1P+N Type A, B curve
Schneider Electric RCBO B Type Single Pole 6A 30mA
B-type single-pole 6A 30mA RCBO for one circuit
Hager RCBO - SP C Curve 20A 30mA 10kA
SP C curve 20A 30mA RCBO, 10kA, 1 module Type A
Eaton RCBO 6A, 1 Pole, B Curve, Type A, 10kA
Eaton 6A RCBO with B curve and 10kA breaking capacity
Start with the space you’ve got in the board and how the circuit will be used. That usually narrows RCBOs faster than anything else. A cramped layout can rule out a larger body or awkward terminal arrangement. The wrong pole count causes trouble later if the circuit needs a different switching arrangement. After that, check the trip characteristic and breaking capacity against the job, not just the label on the front. Most of the swaps I see come from matching the device to the board size, then finding it doesn’t suit the actual circuit once the work’s underway.
A single pole RCBO suits the common domestic setup where you want one circuit isolated cleanly. A double pole RCBO, or 2 pole RCBO, fits circuits that need both conductors switched together.
Type A RCBOs are the usual pick on modern loads with electronics. Type AC still appears on simpler circuits, but it is less often the first choice now.
If you are weighing an RCBO breaker against a combined RCD MCB or RCD MCB combo, the RCBO keeps one fault from taking out the rest of the board. That gives you tighter selectivity and less disruption on the board. Power Distribution & Circuit Protection
What usually decides it is the circuit and the board, not the label on the front. For simple circuits, a single pole rcbo is often enough. If you need both conductors switched, a 2 pole rcbo or double pole rcbo is the usual call. It takes more space and usually costs more.
Type A rcbo is the better fit where the load is less predictable. Type AC still turns up on simpler legacy jobs. If you are building out a board, check the layout against Consumer Units. If the circuit is being controlled rather than just protected, you may need Contactors instead.
Once you’ve picked the RCBOs, the next call is what still needs to sit in the board and what has to be finished off on site.
A tidy board build usually comes down to the right consumer units and the right consumer unit accessories. A cramped enclosure or a missing blanking piece slows the job later. If the install needs more control gear, contactors are the next stop. If it’s only the final board-out, keep the layout simple and use the parts that suit how the circuit is being split.