RCBOs are the usual call when you want fault protection and overcurrent protection on the same way, so you are not relying on a shared device to take out the whole board. Choose the pole count, trip type and breaking capacity to suit the circuit and board spec. Most call-backs come from fitting the wrong format for the enclosure, or from treating every circuit the same when the load and arrangement are different.
Eris Consumer Pro 40A 30mA C Curve 6kA A Type RCBO Single Module 2 Pole Switched…
40A 30mA C curve A type RCBO, single module, 2-pole switched live & neutral
Fusebox 10A 1P+N Switched C Curve 30mA 6kA Type A Bi-Directional Mini RCBO
10A 30mA Type A Bi-Directional Mini RCBO, 1P+N switched, C curve, 6kA
Eaton RCBO - 6A 1 Pole C Curve Type A 10kA
6A 1-pole C Curve Type A RCBO, 10kA
Eris Commercial Pro RCBO - 16A 30mA C Curve 10kA Single Pole
16A C curve 30mA RCBO, single pole, 10kA
Eris Consumer RCBO Compact - 1 pole 30mA 10A B curve Type A 6kA version 2
Compact 10A B curve single pole RCBO with 30mA Type A and 6kA breaking capacity
Fusebox Double Pole Type A B Curve RCBO - 20A
20A double pole Type A B curve RCBO
Niglon 10A RCBO, 1 Pole + Neutral, B Curve, Type A, 6kA
Niglon 10A RCBO, 1 pole + neutral, B curve, Type A, 6kA
ALI Industries Adjustable RCBO MC Incoming Kit - 400A 4 pole
400A 4-pole adjustable RCBO incoming kit for consumer units
Eris Consumer Pro RCBO - 16A 30mA Type A C Curve 6kA Single Module 2 Pole Switch…
RCBO 16A 30mA Type A C Curve 6kA, single module, 2-pole switched
Eris Consumer RCBO - 40A 1 pole 30mA B curve AC type 10kA
40A 1-pole RCBO, 30mA B curve, AC type, 10kA
Start with the space you’ve got in the board and how the circuit will be used. That usually narrows RCBOs faster than anything else. A cramped layout can rule out a larger body or awkward terminal arrangement. The wrong pole count causes trouble later if the circuit needs a different switching arrangement. After that, check the trip characteristic and breaking capacity against the job, not just the label on the front. Most of the swaps I see come from matching the device to the board size, then finding it doesn’t suit the actual circuit once the work’s underway.
A single pole RCBO suits the common domestic setup where you want one circuit isolated cleanly. A double pole RCBO, or 2 pole RCBO, fits circuits that need both conductors switched together.
Type A RCBOs are the usual pick on modern loads with electronics. Type AC still appears on simpler circuits, but it is less often the first choice now.
If you are weighing an RCBO breaker against a combined RCD MCB or RCD MCB combo, the RCBO keeps one fault from taking out the rest of the board. That gives you tighter selectivity and less disruption on the board. Power Distribution & Circuit Protection
What usually decides it is the circuit and the board, not the label on the front. For simple circuits, a single pole rcbo is often enough. If you need both conductors switched, a 2 pole rcbo or double pole rcbo is the usual call. It takes more space and usually costs more.
Type A rcbo is the better fit where the load is less predictable. Type AC still turns up on simpler legacy jobs. If you are building out a board, check the layout against Consumer Units. If the circuit is being controlled rather than just protected, you may need Contactors instead.
Once you’ve picked the RCBOs, the next call is what still needs to sit in the board and what has to be finished off on site.
A tidy board build usually comes down to the right consumer units and the right consumer unit accessories. A cramped enclosure or a missing blanking piece slows the job later. If the install needs more control gear, contactors are the next stop. If it’s only the final board-out, keep the layout simple and use the parts that suit how the circuit is being split.