RCBOs

300 products

RCBOs are the usual call when you want fault protection and overcurrent protection on the same way, so you are not relying on a shared device to take out the whole board. Choose the pole count, trip type and breaking capacity to suit the circuit and board spec. Most call-backs come from fitting the wrong format for the enclosure, or from treating every circuit the same when the load and arrangement are different.

We are unable to determine your Delivery Address - results shown are subject to availability. Register and set your Delivery Address for tailored results.
Filters
Type
Number of Ways
Voltage (V)
Eris Consumer RCBO Compact 2 Pole - 30mA 40A C Curve A Type 6kA

Eris Consumer RCBO Compact 2 Pole - 30mA 40A C Curve A Type 6kA

Eris Consumer RCBO, 2 Pole, 40A, 30mA, C Curve, 6kA, A Type

Eris Consumer RCBO with AFDD - 32A 1 pole + neutral B curve Type A 30mA 6kA

Eris Consumer RCBO with AFDD - 32A 1 pole + neutral B curve Type A 30mA 6kA

32A 1-pole+neutral RCBO with arc fault detection (AFDD), B curve, Type A, 30mA

Hager RCBO - 40A 30mA 10kA SP A B

Hager RCBO - 40A 30mA 10kA SP A B

Hager RCBO 40A 30mA 10kA SP Class A Type B, 1 module

Danson Space Saving RCBO - 10kA 16A 30mA 1P+N B Curve Type A

Danson Space Saving RCBO - 10kA 16A 30mA 1P+N B Curve Type A

Single-module RCBO 16A B-curve 30mA Type A, 10kA breaking capacity, 99.5mm heigh…

Schneider Electric iKQ RCBO - 16A 1P+N C curve 30mA Type A

Schneider Electric iKQ RCBO - 16A 1P+N C curve 30mA Type A

16A 1P+N C curve 30mA Type A RCBO with lockable toggle, DIN rail mount

Danson Mini RCBO - 10A 30mA 230V Type A B-Curve 6kA Single Pole Single Module

Danson Mini RCBO - 10A 30mA 230V Type A B-Curve 6kA Single Pole Single Module

Danson Mini RCBO 10A 30mA Type A B-Curve 6kA single pole single module

Eris Commercial Pro Pro A RCBO Single Pole - 20A 30mA Type A C Curve 10kA

Eris Commercial Pro Pro A RCBO Single Pole - 20A 30mA Type A C Curve 10kA

Single pole RCBO, 20A 30mA Type A C curve with 10kA capacity

Page 9 of 30

For the Trade

Start with the space you’ve got in the board and how the circuit will be used. That usually narrows RCBOs faster than anything else. A cramped layout can rule out a larger body or awkward terminal arrangement. The wrong pole count causes trouble later if the circuit needs a different switching arrangement. After that, check the trip characteristic and breaking capacity against the job, not just the label on the front. Most of the swaps I see come from matching the device to the board size, then finding it doesn’t suit the actual circuit once the work’s underway.

Popular RCBO Formats

A single pole RCBO suits the common domestic setup where you want one circuit isolated cleanly. A double pole RCBO, or 2 pole RCBO, fits circuits that need both conductors switched together.

Type A RCBOs are the usual pick on modern loads with electronics. Type AC still appears on simpler circuits, but it is less often the first choice now.

If you are weighing an RCBO breaker against a combined RCD MCB or RCD MCB combo, the RCBO keeps one fault from taking out the rest of the board. That gives you tighter selectivity and less disruption on the board. Power Distribution & Circuit Protection

Key Differences When Choosing

What usually decides it is the circuit and the board, not the label on the front. For simple circuits, a single pole rcbo is often enough. If you need both conductors switched, a 2 pole rcbo or double pole rcbo is the usual call. It takes more space and usually costs more.

Type A rcbo is the better fit where the load is less predictable. Type AC still turns up on simpler legacy jobs. If you are building out a board, check the layout against Consumer Units. If the circuit is being controlled rather than just protected, you may need Contactors instead.

Next Decisions After Choosing

Once you’ve picked the RCBOs, the next call is what still needs to sit in the board and what has to be finished off on site.

A tidy board build usually comes down to the right consumer units and the right consumer unit accessories. A cramped enclosure or a missing blanking piece slows the job later. If the install needs more control gear, contactors are the next stop. If it’s only the final board-out, keep the layout simple and use the parts that suit how the circuit is being split.

Local availability for RCBOs

TToolstation
Toolstation
CCity Plumbing
City Plumbing
YYesss Electrical (South)
Yesss Electrical (South)
YYesss Electrical (Central)
Yesss Electrical (Central)
YYesss Electrical (North)
Yesss Electrical (North)
MMP Moran
MP Moran
WWFD (KLM) Electrical Supplies
WFD (KLM) Electrical Supplies
GGLT Electrical
GLT Electrical
AABM Electrical Wholesalers
ABM Electrical Wholesalers
AABM Electrical Distributors
ABM Electrical Distributors
LLords Builders Merchants
Lords Builders Merchants
Local availability for RCBOs